PLP

PLP

35-65 kW

The reduction of polluting emissions, whether directly related to the use of greenhouse gases or more indirectly related to emissions from the production of electricity used during the lifetime of a heat pump, is the first and most important pillar on which Galletti has based its Advanced Design solutions. This has led to the creation of PLP, a new range of natural refrigerant air/water units with inverter compressors. Its extremely wide operating range and high performance under all operating conditions make it the perfect answer to the need to phase out the use of fossil fuels for heating and cooling buildings.
  • 3-way external valve management
  • EC scroll compressor
  • Packaged unit
  • Cooling / Heating
  • Cooling
  • Atex A3 gas leak detection
  • R290 refrigerant

PLP

35-65 kW

The reduction of polluting emissions, whether directly related to the use of greenhouse gases or more indirectly related to emissions from the production of electricity used during the lifetime of a heat pump, is the first and most important pillar on which Galletti has based its Advanced Design solutions. This has led to the creation of PLP, a new range of natural refrigerant air/water units with inverter compressors. Its extremely wide operating range and high performance under all operating conditions make it the perfect answer to the need to phase out the use of fossil fuels for heating and cooling buildings.
  • 3-way external valve management
  • EC scroll compressor
  • Packaged unit
  • Cooling / Heating
  • Cooling
  • Atex A3 gas leak detection
  • R290 refrigerant
PLP
  • 3-way external valve management
  • EC scroll compressor
  • Packaged unit
  • Cooling / Heating
  • Cooling
  • Atex A3 gas leak detection
  • R290 refrigerant

Advanced Design Plus

  • Use of natural refrigerant R290 (GWP = 3)
  • Inverter driven variable speed scroll compressor
  • Very high seasonal efficiency values (SCOP up to 4,50 and SEER up to 5,24)
  • Maximum temperature of the water produced 80°C
  • Water produced at 60°C with -20°C external air
  • Finned coil circuitry designed to ensure counter-current exchange between air and refrigerant in every operating mode.
  • Smart Grid Certification

Product advantages

  • Electronic expansion valve as standard
  • Microchannel coil for cooling only versions
  • high configurability and wide availability of accessories
  • On-board hydronic kit with 2 pumps and 1 buffer tank
  • Advanced logics for securing the unit in the event of refrigerant leaks

Available versions

  • 5 models
  • Cooling only
  • Reversible heat pump
  • Low noise acoustic configurations

Technical specifications

Find how an advanced design solution is born: advanceddesign.galletti.com

PLP is Galletti’s new range of air-cooled packaged chillers and heat pumps for outdoor installation equipped with a modulating scroll compressor driven by an inverter and characterized by the use of R290 refrigerant. R290 (Propane) is a natural refrigerant capable of guaranteeing one of the lowest GWPs on the market, equal to only 3. This GWP value ensures that the PLP range complies with the gradual reduction of greenhouse gas emissions required by the F-GAS regulation. Not only that, the use of finned coils with reduced diameters for the passage of the refrigerant allows a reduction of the refrigerant charge by more than 50% compared to similar products with same capacity but with standard technology.

The range consists of 5 models with heating capacities from 35 to 65 kW, available as heating only and reversible heat pump mode. The inverter controller allows to adjust the capacity to the actual thermal load and makes it possible to considerably reduce electrical intakes at the compressor start-up (reduction of starting currents) and during the operation under partial loads. This is why it is possible to achieve some of the highest seasonal efficiency indices on the hVAC market: SCOP up to 4.50 and SEER up to 5.24.

The use of top quality components at the cutting edge of technology in the cooling, hydraulic, and electrical systems makes PLP chillers state of the art in terms of efficiency, reliability, and operating limits. In fact, the ability to produce water from -10°C to 80°C, and full load operation with external air from -20°C to 48°C. With -20°C external air, the production of hot water at 60°C is still possible.

The range allows high configurability from an acoustic and hydraulic point of view, having ample accessories designed to meet installation needs characterized by reduced overall dimensions: without increasing the size it is possible to provide on board the storage tank and up to a maximum of two hydraulic pumps.

Advanced control, which is always provided across the entire range, allows continuous monitoring of operating parameters, advanced regulation logics, and connectivity and the management of advanced procedures for making the unit safe in the event of refrigerant leaks (A3).

Related documents and files

CE_Declaration_PLP_Rev.0

Size: 0,151 MB

CE_Declaration_PLP_Rev.0

sales brochure

Size: 1,198 MB

sales brochure

EU 2016/2281

Size: 0,768 MB

EU 2016/2281

Guidelines_for_Promoting_A2L-A3_units

Size: 0,661 MB

Guidelines_for_Promoting_A2L-A3_units

installation manual

Size: 5,160 MB

installation manual

technical manual

Size: 3,194 MB

technical manual

PLP - Technical brochure - EN

Size: 13,978 MB

PLP - Technical brochure - EN

Service center

Find the nearest service center

Find your local agent

We have several customized packages for your property. Fill out the form with the required details and we will contact you.

Request information

Click here and fill the form to ask for information on PLP

Request more information